Search results for " Mass"
showing 10 items of 5048 documents
Anthropometric measures of 9-to 10-year-old native tibetan children living at 3700 and 4300m above sea level and han Chinese living at 3700m
2015
A high residential altitude impacts on the growth of children, and it has been suggested that linear growth (height) is more affected than body mass. The aim of the present study was to estimate the prevalence of obesity, overweight, underweight, and stunting in groups of native Tibetan children living at different residential altitudes (3700 vs 4300 m above sea level) and across ancestry (native Tibetan vs Han Chinese children living at the same altitude of 3700 m), as well as to examine the total effect of residential altitude and ancestry with stunting. Two cross-sectional studies of 1207 school children aged 9 to 10 years were conducted in Lhasa in 2005 and Tingri in 2007. Conventional …
Quartz resonators for penning traps toward mass spectrometry on the heaviest ions
2020
We report on cyclotron frequency measurements on trapped 206,207Pb+ ions by means of the non-destructive Fourier-transform ion-cyclotron-resonance technique at room temperature. In a proof-of-principle experiment using a quartz crystal instead of a coil as a resonator, we have alternately carried out cyclotron frequency measurements for 206Pb+ and 207Pb+ with the sideband coupling method to obtain 21 cyclotron-frequency ratios with a statistical uncertainty of 6 × 10−7. The mean frequency ratio R¯ deviates by about 2σ from the value deduced from the masses reported in the latest Atomic Mass Evaluation. We anticipate that this shift is due to the ion–ion interaction between the simultaneousl…
Fluence effect on ion-implanted As diffusion in relaxed SiGe
2005
A systematic study on the fluence (5 × 108 − 4 × 1014 cm−2) dependence of ion-implanted As diffusion in relaxed Si1 − xGex alloys (with x = 0.2, 0.35 and 0.5) and silicon has been performed by the modified radiotracer and secondary ion mass spectrometry techniques. With fluences above 4 × 1011 cm−2 a clear fluence-dependent enhancement in arsenic diffusion was noted for Si1 − xGex. In case of arsenic-implanted silicon such fluence dependency was not observed. This can be assigned to enhanced implantation-induced damage formation and more deficient radiation damage recovery of SiGe.
HCl gas gettering of low-cost silicon
2013
HCl gas gettering is a cheap and simple technique to reduce transition metal concentrations in silicon. It is attractive especially for low-cost silicon materials like upgraded metallurgical grade (UMG) silicon, which usually contain 3d transition metals in high concentrations. Etching of silicon by HCl gas occurs during HCl gas gettering above a certain onset temperature. The etching rate as well as the gettering efficiency was experimentally determined as a function of the gettering temperature, using UMG silicon wafers. The activation energy of the etching reaction by HCl gas was calculated from the obtained data. The gettering efficiency was determined by analyzing Ni as a representativ…
Annealing behaviour of aluminium-implanted InP
2000
The annealing behaviour of aluminium has been studied in single-crystal InP implanted with 40 and 120 keV 27Al+ ions. The implantation doses were 1 x 1015 and 1 x 1016 cm-2. The aluminium concentration profiles were determined by two techniques, Secondary ion mass spectrometry (SIMS) and the nuclear resonance broadening technique (NRB) which was used for checking purposes. The usability of the SIMS technique for profiling Al rich layers was studied. Significant inconsistencies were observed in the SIMS profiles with the high dose implanted samples. The 120 keV, 1 x 1016 cm-2 implanted samples were subject to annealing in argon atmosphere in the temperature range 380–600°C. Redistribution an…
Charge breeding at GANIL: Improvements, results, and comparison with the other facilities
2019
International audience; The 1+/n+ method, based on an ECRIS charge breeder (CB) originally developed at the LPSC laboratory, is now implemented at GANIL for the production of Radioactive Ion Beams (RIBs). Prior to its installation in the middle of the low energy beam line of the SPIRAL1 facility, the 1+/n+ system CB has been modified based on the experiments performed on the CARIBU Facility at Argone National Laboratory. Later, it has been tested at the 1+/n+ LPSC test bench to validate its operation performances. Charge breeding efficiencies as well as charge breeding times have been measured for noble gases and alkali elements. The commissioning phase started at GANIL in the second half-y…
On-line commissioning of SHIPTRAP
2006
Abstract The on-line commissioning of the Penning-trap mass spectrometer SHIPTRAP was successfully completed with a mass measurement of holmium and erbium radionuclides produced at SHIP. A large fraction of contaminant ions created in the stopping cell was identified to originate from the buffer-gas supply system. Using a liquid nitrogen cold trap they were reduced to a tolerable amount and mass measurements of Er 147 , Er 148 , and Ho 147 with relative uncertainties of about 1 × 1 0 − 6 were performed.
Analysis of psychoactive substances in water by information dependent acquisition on a hybrid quadrupole time-of-flight mass spectrometer.
2016
Emerging drugs of abuse, belonging to many different chemical classes, are attracting users with promises of “legal” highs and easy access via internet. Prevalence of their consumption and abuse through wastewater-based epidemiology can only be realized if a suitable analytical screening procedure exists to detect and quantify them in water. Solid-phase extraction and ultra-high performance liquid chromatography quadrupole time-of-flight-mass spectrometry (UHPLC–QqTOF–MS/MS) was applied for rapid suspect screening as well as for the quantitative determination of 42 illicit drugs and metabolites in water. Using this platform, we were able to identify amphetamines, tryptamines, piperazines, p…
Aerosol Chemistry Resolved by Mass Spectrometry: Linking Field Measurements of Cloud Condensation Nuclei Activity to Organic Aerosol Composition.
2016
Aerosol hygroscopic properties were linked to its chemical composition by using complementary online mass spectrometric techniques in a comprehensive chemical characterization study at a rural mountaintop station in central Germany in August 2012. In particular, atmospheric pressure chemical ionization mass spectrometry ((-)APCI-MS) provided measurements of organic acids, organosulfates, and nitrooxy-organosulfates in the particle phase at 1 min time resolution. Offline analysis of filter samples enabled us to determine the molecular composition of signals appearing in the online (-)APCI-MS spectra. Aerosol mass spectrometry (AMS) provided quantitative measurements of total submicrometer or…
Aerosol Chemistry Resolved by Mass Spectrometry: Insights into Particle Growth after Ambient New Particle Formation
2016
Atmospheric oxidation of volatile organic compounds (VOCs) yields a large number of different organic molecules which comprise a wide range of volatility. Depending on their volatility, they can be involved in new particle formation and particle growth, thus affecting the number concentration of cloud condensation nuclei in the atmosphere. Here, we identified oxidation products of VOCs in the particle phase during a field study at a rural mountaintop station in central Germany. We used atmospheric pressure chemical ionization mass spectrometry ((-)APCI-MS) and aerosol mass spectrometry for time-resolved measurements of organic species and of the total organic aerosol (OA) mass in the size r…